THERMOSTAT JACKET TUBE XK26/20
产品名称: THERMOSTAT JACKET TUBE XK26/20
英文名称: THERMOSTAT JACKET TUBE XK26/20
产品编号: 18-1000-82
产品价格: 0
产品产地: 美国
品牌商标: GE
更新时间: null
使用范围: null
- 联系人 :
- 地址 : 上海市宝山区友谊路1506号东智广场1109室
- 邮编 : 201900
- 所在区域 : 上海
- 电话 : 138****5983 点击查看
- 传真 : 点击查看
- 邮箱 : 342786402@qq.com
18-1000-82 | THERMOSTAT JACKET TUBE XK26/20 |
18-1000-83 | THERMOSTAT JACKET TUBE XK50/20 |
18-1000-84 | CHROM TUBE XK26/20 |
18-1000-85 | CHROM TUBE XK50/20 |
18-1000-98 | COLUMN HR 16/5 |
18-1031-47 | BOTTOM PIECE COMPLETE, XK 16 |
18-1031-48 | BOTTOM PIECE COMPLETE, XK 26 |
18-1031-49 | BOTTOM PIECE COMPLETE, XK 50 |
18-1031-80 | PLUNGER, XK 16 |
18-1031-81 | PLUNGER, XK 26 |
18-1101-28 | FILTER 26 MM KIT |
18-1152-82 | TRICORN O-RING PACKING KIT |
18-1153-01 | TRICORN 5 COLUMN BOTTOM UNIT |
18-1153-02 | TRICORN 5 FILTER KIT |
18-1153-03 | TRICORN O-RING 3X1 PFR |
18-1153-04 | TRICORN 5/20 GLASS TUBE |
18-1153-05 | TRICORN 5/50 GLASS TUBE |
18-1153-06 | TRICORN 5/100 GLASS TUBE |
18-1153-07 | TRICORN 5/150 GLASS TUBE |
18-1153-08 | TRICORN 5/200 GLASS TUBE |
18-1153-10 | TRICORN 10 COLUMN BOTTOM UNIT |
18-1153-11 | TRICORN 10 FILTER KIT |
XK and K 9 Series Columns and Accessories
- User friendly and robust empty columns, designed for liquid chromatography at low to medium pressure.
- Plunger design to ensure a homogeneous buffer distribution and reproducible packing
- Adapter QuickLock mechanism that facilitates column handling and cleaning
- Fittings for direct connection to chromatographiy systems
- Cooling jacket for sensitive purifications
- K 9 columns should be used for low pressure applications and are available in three lengths without flow adapters.
XK and K 9 Series Columns and Accessories
Technical Information
XK columns are compatible with most laboratory media.
XK empty columns are designed for liquid chromatography at low to medium pressure. The user-friendly design ensures trouble-free operation with fittings for direct connection to ÄKTA design instruments or other high-performance liquid chromatography systems. The product family is based on a robust design for high reproducibility and accurate results. XK columns are compatible with aqueous solutions and most organic solvents used in liquid chromatography of macromolecules.
XK empty columns provide reliable and reproducible separations. The tube material is of borosilicate glass, which allows for visual inspection of the media bed. The columns are made of biocompatible materials that exhibit excellent chemical resistance. A broad range of column dimensions makes XK columns suitable for many different purification needs. Column packing can be performed using either a packing reservoir or an extra column tube attached with a packing connector. The QuickLock mechanism of the adapter shaft facilitates rapid and easy movement of the adapter, simplifying adjustments of the bed height, disassembly, and cleaning. The design of the adapter plunger gives a uniform flow, which maintains the integrity of the packed bed during operations. An extensive range of spare parts is available, facilitating maintenance.
XK empty columns are available in three dimensions, each with several lengths see below:
TECHNICAL SPECIFICATIONS | |||
Length (cm) | i.d. 50 mm | ||
20 | XK 16/20 | XK 26/20 | XK 50/20 |
30 | - | - | XK 50/30 |
40 | XK 16/40 | XK 26/40 | - |
60 | - | - | XK 50/60 |
70 | XK 16/70 | XK 26/70 | - |
100 | XK 16/100 | XK 26/100 | XK 50/100 |
TECHNICAL SPECIFICATIONS | |
Operating pressure | |
XK 16, XK 26 | < 5 bar (72 psi, 0.5 MPa) |
XK 50 | < 3 bar (43 psi, 0.3 MPa) |
K 9 | < 1 bar (14.5 psi, 0.1 MPa) |
Operating temperature | |
XK | 4°C-40°C |
K 9 | 4°C-40°C |
pH stability | |
XK | 1-14 |
K 9 | 2-10 |
Materials in contact with eluent | |
XK | Borosilicate glass, polyamide, fluororubber, EPDM, TEFZEL, superpolyoxymethylene |
K 9 | Acrylic plastic, polyamide, fluororubber, polypropylene, superpolyoxymethylene |
Chemical stability | Resistant to aqueous solutions and solvents used in liquid chromatography. Not resistant to acetone, ketones, chlorinated hydrocarbons, aliphatic esters, and phenol. Should be avoided: >10% NaOH, > 10% HCl, > 5% acetic acid, and strong mineral acids. |
Mesh size of net | |
XK | 10 μm, nylon |
K 9 | 10 or 80 μm, nylon |
TECHNICAL SPECIFICATIONS ¾ XK/K Columns Bed Volumes and Heights | ||||||||
Column Size | Without Adapter | With One Adapter | With Two Adapters | |||||
i.d. | Length | Volume | Bed Height | Volume | Bed Height | Volume | Bed Height | |
(mm) | (cm) | (ml) | (cm) | (ml) | (cm) | (ml) | (cm) | |
K 9/15 | 9 | 15 | 9 | 14 | - | - | - | - |
K 9/30 | 9 | 30 | 18 | 29 | - | - | - | - |
K 9/60 | 9 | 60 | 38 | 59 | - | - | - | - |
XK 16/20 | 16 | 20 | - | - | 5-31 | 2.5-15 | 0-31 | 0-15.5 |
XK 16/40 | 16 | 40 | - | - | 45-70 | 22.5-35 | 16-70 | 8-35 |
XK 16/70 | 16 | 70 | - | - | 105-130 | 52.5-65 | 76-130 | 38-65 |
XK 16/100 | 16 | 100 | - | - | 165-190 | 82.5-95 | 136-190 | 68-95 |
XK 26/20 | 26 | 18 | - | - | 5.3-66 | 1-12.5 | 0-66 | 0-12.5 |
XK 26/40 | 26 | 40 | - | - | 122-186 | 23-35 | 45-186 | 8.5-35 |
XK 26/70 | 26 | 70 | - | - | 281-344 | 53-65 | 204-344 | 38.5-65 |
XK 26/100 | 26 | 100 | - | - | 440-504 | 83-95 | 363-504 | 68.5-95 |
XK 50/20 | 50 | 18 | - | - | 0-274 | 0-14 | 0-274 | 0-14 |
XK 50/30 | 50 | 30 | - | - | 265-559 | 13.5-28.5 | 0-559 | 0-28.5 |
XK 50/60 | 50 | 60 | - | - | 794-1088 | 40.5-55.5 | 500-1088 | 25.5-55.5 |
XK 50/100 | 50 | 100 | - | - | 1588-1862 | 81-95 | 1274-1862 | 65-95 |
http://www.gelifesciences.com/aptrix/upp01077.nsf/Content/Products?OpenDocument&moduleid=10987